型号 |
S-400-12 |
S-400-15 |
S-400-24 |
S-400-36 |
S-400-48 |
直流输出电压 |
12V |
15V |
24V |
36V |
48V |
输出电压容差(注2) |
±2% |
±2% |
±1% |
±1% |
±1% |
额定输出电流 |
33A |
26.6A |
16.6A |
11A |
8.3A |
输出电流范围 |
0-33A |
0-26.6A |
0-16.6A |
0-11A |
0-8.3A |
纹波及噪音(注3) |
150mVp-p |
150mVp-p |
150mVp-p |
150mVp-p |
200mVp-p |
进线稳定度(注4) |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
负载稳定度(注5) |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
直流输出功率 |
396W |
399W |
398W |
396W |
396W |
效率 |
80% |
81% |
83% |
83% |
84% |
直流电压可调范围 |
±10% |
±10% |
±10% |
±10% |
±10% |
输入电压范围 |
90~132VAC/180~264VAC由开关选择47~63Hz;254~370VDC |
||||
输入电流 |
6A/115V 3A/230V |
||||
冲击电流 |
25A/115V 50A/230V |
||||
漏电流 |
<3.5mA/240VAC |
||||
过载保护 |
105%~135% 类型:切断输出 复位:自动恢复 |
||||
过电压保护 |
输出电压的115%~135% |
||||
温度系数 |
±0.03%/℃(0-50℃) |
||||
启动、上升、保持时间 |
200ms,100ms,30ms |
||||
抗震性 |
10~500Hz,2G 10min,/1周期,时长60分,各轴 |
||||
耐压性 |
输入输出间:1.5KvAC输入与外壳:1.5KvAC输出与外壳:0.5KvAC |
||||
隔离电阻 |
输入输出间:输入与外壳,输出与外壳:500VDC/100MΩ |
||||
工作温度、湿度 |
-10℃~+60℃(参考输出特性图),20%~90%RH |
||||
外形尺寸 |
215×115×50mm |
||||
重量 |
1.15Kgs |
||||
安全标准 |
GB4949,UL60950,EN60950 |
||||
EMC标准 |
依据GB9254 EN55022 EN55024 A级设计 |
||||
备注: 1、以上参数测试条件为:230VAC输入,额定负载,25℃ 70%RH,湿度。 2、容差:包括庙宇容差,线路稳定度,负载稳定度(注5)。 3、纹波测试:20MHz用“A12”双绞线,中断用0.1uF—47uF电容器短路。 4、进线电压稳定度测试:满负载时时线最低电压到最高电压。 5、负载稳定度测试:负载从0%到100%。 6、C3、4必须拆除。 |